Technical Spec
Details on the theatre, in technical dimensions and downloadable documents.
All documents listed are PDF files and require acrobat reader or equivalent to view except the complete Theatre Royal survey is a .dwg file.
Click the document name and save to your desktop to review them.
General Loose Equipment
- Orchestra Pit
- 18 No. Music Stand
18 No. Music Stand Light
1 No. Conductor Music Stand
- Stage
- 15 No. 1-2 Metre Stage Brace
6 No. 1-3 Metre Stage Brace
12 No. Stage Weight
10 No. Swivel Coupler
40 No. Boomarm
- Equipment
- 10 No. (approx) 13A 4 Gang Plug Board
3 No. (approx) 13A 30M Extension Reel
15 No. (approx) 13A IEC
Various leads and adaptors - ring tech manager for details
- Power Tools
-
1 No. Power Drill
1 No. Jigsaw
1 No. Angle Grinder
1 No. Circular Saw
All Essential Hand Tools
- Ladders
- 1 No. 4.1M Zarges Combination Ladder
1 No. 8.35M, 2 Part, Extension Ladder
2 No. Step Ladder
Various rigging, conduit, and fixings - ring tech manager for details
Backstage Accommodation
- Green Room
- Access: DSL Corner
It is possible to use the Green Room as a Dressing Room. However, advanced notice must be given to the Technical Manager.
- Dressing Rooms
- 2 No. Dressing Room
Located: 3rd Floor (Upper Circle)
Access: DSL Corner, through Green Room
Power Supplys
- Stage
- 1 No. 5 Pin Cee F - 63A TPN General Purpose, located in Scene Dock
1 No. 3 Pin Cee F - 32A SPN (Clean Earth), located in Scene Dock
- Tech Gallery
- 63A TPN Switched Isolator
- General Purpose
- 13A Twin Gang, to all areas
- Clean Earth Supply
- 13A Twin Gang, to all areas
Comms
- Show Relay
- Show Relay to: Green Room, Control Room and Box Office, via over stage Microphone and Dual 100v Line Speakers
- Paging
- Stage Manager's Paging to all Backstage Areas from control room or stage managers desk
- Talkback
- Talkback Inputs wired to all areas of Stage, Fly Gallery, Control Room, Orchestra Pit, etc.
ASL Pro Dual Channel Base Station (located in Comms Rack)
6 No. Single Channel Belt Pack
2 No. Dual Muff Headset
4 No. Single Muff Headset
- System Management
- 2 No. Allen & Heath IDR & Hub
- Stage CCTV
- CCTV Monitor Inputs wired to Stage, Control Room, Orchestra Pit, Green Room, Foyer, Box Office and Dress Circle
1 No. Colour Camera, complete with, IR Gun, located in the Upper Circle
4 No. CCTV Monitor
- Stage Managers Desk
- Loom Input DSL and DSR
Hard of Hearing / Voice Description
Sennheiser IR Modulator, located in Comms Rack
Sennheiser IR Panels, located around Auditorium
Voice Description Mic Insert in Control Room, at rear of Stalls
PA System
- Mixing Desks
- 1 No. Yamaha 01V Digital Mixing Console
1 No. Yamaha LS9 32 Digital Mixing Console
- Amplifiers
- 1 No. Nexo NX 4x4 Power Amp (use for front of house system)
1 No. Nexo NX 4x1 Power Amp (use for front of house system)
1 No. Nexo NX 4x1 Power Amp (use for on stage or spare)
- FOH Speakers
- 2 No. Nexo Ps15 Full Range Cabinet
4 No. Nexo Ps10 Full Range Cabinet
2 No. Nexo Ls600 Sub Bass
- Loose Speakers
- 4 No. Nexo Ps10 Full Range Cabinet
- Stage Mic/Line
- DSR: 12 No. Sends, 4 No. Returns
DSL: 12 No. Sends, 4 No. Returns
USR: 6 No. Sends
USL: 6 No. Sends
Orchestra Pit [right]: 12 No. Sends, 4 No. Returns
Orchestra Pit [left]: 6 No. Sends.
Fly Gallery:All above wired to Control Mic/Line Patch
- Speaker Outlets
- 440 No. NL-4 Speaker Outlets, available throughout stage and orchestra pit, via patch @ Amp Rack
- Playback
- Hard Drive PC
1 No. Denon DN-C110 CD Player
- Microphones / D.I.
- 6 No. Shure SM58 Mic
6 No. Black Boom Stand
2 No. Black Table Stand
2 No. BSS AAR133 DI Box
4 No. Behringer Ultra-Di Di-100
4-way Trantec Hand Held System, inc. 4 Hand Held Mic
1 No. T.Bone DC1000 Drum Mic set
2 No. T.Bone TWS LAVALIERSET 800mhz
- Cable
- Contact Technical Manager for details
- Mix Position
- Control Room [Centre Rear Auditorium Stalls]
Please note: Mix position is strictly in Control Room Only
House Lighting
- Control
- ETC Unison Architectural Control
Various outstations located around stage, backstage, control and box office
System also controls all Blue/White Work Light
- Fittings
- Dali PL
LED Down Lighters
Chandelier
- Zones
- All levels and groups of seating areas are wired in separate zones / circuits, for separate control.
Production Lighting
- Dimmers
- 126 No. Strand Wallmount 2.5kw
- Circuits
- Onstage:
5 No. 12-way, 16amp, Internally Wired Bars
3 No.16amp DSL, DSR, USL, USR
FOH:
Upper Circle: 36 No. 16amp, in Semi Circular, Internally Wired Bar
Dress Circle: 12 No. 16amp, SL and SR, Internally Wired Bar
- Control
- 1 x Strand Palette VL 6400 500 Console
1 x Strand 520i
DMX / Ethernet distributed to all areas, via Control Network, DMX Merge and Splitter & Patch on SL Gallery
- Lanterns
- 8 No. ETC Source 4 PAR EA Lantern
20 No. CP PAR Lantern, complete with, CP62
12 No. Iris 1 Flood Lantern
20 No. Selecon Rama, 1200 watt, ACCF Fresnel Lantern
8 No. Selecon Rama, 1200 watt, PC Fresnel Lantern
8 No. Source 4 Zoom 15/30 Lantern, complete with, Iris and Gobo Holder
8 No. Source 4 Zoom 25/50 Lantern, complete with, Iris and Gobo Holder
8 No. Source 4 Zoom 14 Degree lantern, complete with, Iris and Gobo Holder
2 No. R.J. Ginger, 2000 watt Follow Spot
1 No. Martin Hazer (fluid not supplied)
Please note: Theatre Royal does not supply color
- LAMP
- Selection of Lamps Available, Contact Technical Manager for details.
- Cable
- V2 No. 5M Socapex Cable
3 No. 10M Socapex Cable
4 No. 15M Socapex Cable
11 No. Fan Tail Out Cable
3 No. Fan Tail In Cable
30 No. 5M 16A Extension Cable
18 No. 10M 16A Extension Cable
20 No. 15M 16A Extension Cable
19 No. Y Cord 16A Splitter Cable
11 No. 16A Trelco Block
16 No. 16A - 15A Jump Cables
Small Selection of 16A - 15A Jump Cable, 16A - 13A Jump Cable, etc. available
2 No. 20M DMX-DMX Cable
4 No. 10M DMX-DMX Cable
Selection of cables Available, Contact Technical Manager for details.
Drapes and Masking
- House Tabs
- Velvet, on No. 1 Motor Set, with Variable Speed Control @ DSR
-
- Permanent Velvet House Border
- BWS Drapes
- 2 No. Black Wool Serge.
Width: 6,200mm (approx.)
Drop: 2,500mm (approx.)
- BWS Borders
- 5 No. Black Wool Serge, Masking Borders.
Width: 6,200mm (approx.)
Drop: 2,500mm (approx.)
- BWS Legs
- 8 No. Black Wool Serge, Masking Legs.
Width: 2,000mm (approx.)
Drop: 6,500mm (approx.)
Complete with, 8 No. Spring Action Swivel Sets
- Cyclorama
- 1 No. Filled Cloth Cyclorama.
Width: 6,200mm (approx.)
Drop: 6,500mm (approx.)
Stretched on Aluminum Frame
- Masking Flat
- 4 No. 14ft x 4ft Masking Flats
1 No. 3ft extensions available on request
Flying and Rigging
- Motorised Sets
- 6 No. Hauling Bar
Travel Speed: 3 Second / Metre
Max Loading: 500kg
Length: 9,000mm
- Hemp Sets
- 10 No. Hauling Bar
Max Loading: 120kg
Length: 9,000mm
- Side Sets
- 2 No. Manual Winched Raise & Lowers Sets
Max Loading: 250kg
- Auditorium
- No Rigging Points separate from existing
Lighting Bars
Auditorium
- Level 1
- Stalls - 177 No. Fixed tip up seats, on a raked floor
- Level 2
- Dress Circle - 165 No. Fixed tip up seats on a a raked tier
- Level 3
- Upper Circle - 88 No. Fixed tip up seats on a a raked tier
- Control Room
- Positioned: Rear of Stalls
Access: Direct from Backstage, via The Foyer
Enclosed Room, with Sliding Windows
Stage Area
-
- Proscenium Stage
- Stage Floor
- Flat. Softwood Timber on Battens (painted black).
- Cross Over
- Long route via a series of backstage corridoors.
- Safety Curtain
- Safety Curtain immediately US of Proscenium
(Safety Curtain must be able to fly in at all times during performance)
- Pros Width
- 6,200mm (from pros to pros)
- Pros Height
- 6,400mm (from stage to pros)
- Gallery Width
- 9,790mm (from fly gallery to tech gallery)
- Stage Width
- 12,400mm (from side wall to side wall @ pros line)
12,200mm (from side wall to side wall @ US line)
- Stage Height
- 1,100mm (from auditorium floor to stage)
13,500mm (from stage to grid underside)
7,010mm (from stage to fly / tech gallery)
- Stage Dept
- 5,500mm (SR, from US line to safety curtain)
7,500mm (SL, from US line to safety curtain)
- Apron
- Stage Extension / Pit Cover, available at request. Extends Stage Depth by 1,800mm @ Centre Line. Ask Technical Manager for details.
- Orchestra Pit
- Curved Permanent Pit, in front of stage, extending 1,800mm (approx.)
Access: via Backstage, or FOH, Stairwell
Accommodation: 18 - 25 (approx.)
- Storage
- Very limited scenery storage space available.
General Information
- Building
- 430 Seat classical Victorian Theatre with Proscenium stage and 3 seating levels.
- Address
- The Mall, Waterford.
- Phone
- +353(0) 51 853626
- Email
- info@theatreroyalwaterford.com
- Contacts
- Management Mary Boland
manager@theatreroyalwaterford.com
Technical John Grubb
tech@theatreroyalwaterford.com